Section 3 Front Panel Operation
3.36
The total number of bus events which occurred since
[REC]
was
enabled. Total count can be from 0 to 99,999,999 events.
Recorded 00000
Number of bus events which have been recorded since
[REC]
was
enabled. Recorded count can be from 0 to 32,768.
Pre Count 00000000
Total number of bus events that occurred prior to the trigger since
[REC]
was enabled. Pre count can be from 0 to 99,999,999.
Pre Recorded 00000
Number of bus events currently in record memory that occurred
prior to the trigger. Pre recorded count can be from 0 to 32,768.
Post Count 00000000
Number of bus events that occurred after the trigger since
[REC]
was enabled. Post count can be from 0 to 99,999,999.
Post Recorded 00000
Number of bus events currently in record memory that occurred after
the trigger. Post recorded can be from 0 to 32,768.
Trigger 00000
Record memory location of the trigger point. Trigger can be
EMPTY
or be from 0 to 32,767.
First 00000