Section 4 Serial Controller
4.72
[
state
]
state
is the state of a bus management line. A slash
[
/
]
indicates unasserted,
[
X
]
means "don't care". The absence of a slash
[
/
]
or
[
X
]
means true (asserted). Any bus management line is "don't care"
if not specified.
[
line
]
line
are bus management lines, one or more of:
ATN
,
REN
,
EOI
,
IFC
,
SRQ,
or
ALL
.
[
byte
]
Selects a bus data byte trigger condition.
byte
may be specified
in Binary (%01001010) (all eight digits must be specified),
Decimal (122), Hexadecimal (&H3F) (both digits must be
specified), or ASCII ('A). In binary or hexadecimal format, an X
may be used to specify "don't care".
# OF MATCHES
[
match count
]
Skip
match count
occurrences of the trigger pattern before
recording data.
match count
is from 1 to 65,535.
TRIG DELAY
[
delay count
]
Skip
delay
count
bus events after the trigger pattern
is matched before recording data.
delay
count
is from 0 to
9,999,999.
POST COUNT
[
post count
]
Record
post count
bus events after
match count
occurrences of the trigger pattern and
delay count
events have
occurred.
post
count
is from 0 to 32,767.
WHEN COMPLETE [STEP | STOP
]
Select the action taken at the end of the recording sequence. If
STEP
is selected,
HANDSHAKE
will be changed to
STEP
at the end of
the recording sequence. If
STOP
is selected, data recording will stop at the
end of the recording sequence and the bus will run at the current
HANDSHAKE
speed.