Section 4 Serial Controller
4.27
DISPLAY
The
DISPLAY
command allows the user to display an alphanumeric message on
the 20 character front panel display of the Analyzer488.
A message may be up to 20 characters long. If a message string is longer than
20 characters, only the first 20 characters will be displayed. A space
' '
or null
string
''
will clear the display.
This command does not have a query option.
TYPE System command
SYNTAX
DISPLAY
{
[
'
string
'
]}
string
is any alphanumeric character string.
RESPONSE The first 20 characters of
string
are displayed on the front panel
display of the Analyzer488.
MODE any
BUS STATES None
QUERY None
RESPONSE
EXAMPLES PRINT#1,"DISPLAY'Analyzer488'"
PRINT#1,"DISPLAY' '"