Section 4 Serial Controller
4.60
RECORD
The
RECORD
command enables or disables the recording of bus data.
RECORD
ON
causes the Analyzer488 to begin recording bus events into the record memory.
RECORD OFF
stops recording bus events.
There is an interaction between the
RECORD
and the
SET TRIGGER
commands. If Triggering is disabled (by issuing the
SET TRIGGER OFF
command),
recording will begin upon receipt of the
RECORD ON
command and will stop upon
receipt of the
RECORD OFF
command.
If Triggering is enabled (by issuing the
SET TRIGGER ON
command),
recording will begin upon receipt of the
RECORD ON
command. If
WHEN
COMPLETE STOP
is selected, recording will stop when
match count
occurrences
of
match
have occurred,
trig delay
events have occurred, and
post count
events have occurred.
If
WHEN COMPLETE STEP
is selected, recording will remain on until the
RECORD OFF
command is received. Each time the
STEP
command is sent, the
post
count
value returned by the
STATUS 4
and
STATUS 5
commands will be
incremented.
The query option,
RECORD?
, returns the string,
RECORD ON
, if record is
enabled or
RECORD OFF
if recording is disabled.
TYPE Record command
SYNTAX
RECORD {[?]|[ON|OFF]}
RESPONSE None
MODE Any
BUS STATES None
QUERY
RECORD ON
if record is enabled or
RECORD OFF
if record is
RESPONSE disabled.
Commentaires sur ces manuels