Perform the following procedure to measure the frequency input of each channel. Refer to Figure 1-4 for the
wire connection.
1. Power on and run the test.exe application.
2. Press 2
3. Press $012[Enter] Receive=!01500600
4. Press 2
5. Press %0101510600[Enter] Receive=>!01
6. Press 2
7. Press $01B0[Enter] Receive=!01
8. Press 2
9. Press #010[Enter] Receive=>????????
10. Press 2
11. Press #011[Enter] Receive=>????????
In step 3: the status of CB-7080 is COUNTER mode.
In step 5: Change to frequency mode.
In step 7: Select non-isolated input.
In step 9: Frequency measurement of channel-0.
In step 11: Frequency measurement of channel-1.
Note
The command $01B1 that is referenced in step 7 can be used to select the isolated input. The commands
$01B2 and $01B3 are used for the other selections.