Measurement-computing WaveView Manuel d'utilisateur Page 19

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 48
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 18
WaveView
03-05-02
WaveView, pg. 17
The remaining columns apply only to the WBK17 module.
Reference Note:
Refer to the WBK17 Document Module (in the WBK Option Cards and Modules Users Manual,
p/n 489-0902) for detailed information regarding the various modes. The WBK17 document
module includes explanations, block diagrams, and examples.
WaveView Configuration Window Showing WBK17-Dedicated Columns
Counter Mode
Applies to WBK17 Only
.
WaveView supports several counter modes and can receive input
from up to two encoders (in 1X, 2X, or 4X modes).
All WBK17 modes are detailed in the WBK17 Document Module.
Note
:
The Encoder Mode can only be selected on WBK17
channels x-1 and x-5. Inputs B and Z must be
connected to the next consecutive channels.
Counter Mode Pull-Down List
Reference Note:
Refer to the WBK17 Document Module (in the WBK
Option Cards and Modules Users Manual,
p/n 489-0902) for additional information regarding the
following counter modes.
Counter
The counter makes use of a 16-bit counter (Counter Low), or a 32-bit counter (Counter High). While
in this mode, the channels input increments the counter. The counter is cleared at the beginning of
each scan, and the value [just prior to clearing] is latched and returned to the WaveBook/516, /512A,
or WaveBook/516A. See the upcoming Programmer Note.
Totalize
The totalize mode makes use of a 16-bit counter (Counter Low), or a 32-bit counter (Counter High).
While in this mode, the channels input increments the counter and rolls it over, resulting in a
cumulative total for the counter value. (see the following Programmer Note)
Programmer Note:
In regard to programming, the Counter Mode involves selecting the Clear on Read option
within a single Counter/Totalize Mode; and the Totalize Mode involves selecting the
Totalize option. In WaveView, the Counter and Totalize modes are treated as two distinct
modes.
Note that the
Clear on Read
mode is not available when using an external clock.
Refer to the WBK17 Document Module (in the WBK Option Cards and Modules Users Manual,
p/n 489-0902) for additional information.
T
hese 7 columns apply only to WBK17 modules.