Vue de la page 109
Appendix C IBERR
Programming Reference Manual C-4 GPIB-488
EABO—I/O operation aborted
Cause: I/O operation aborted. (time-out)
Solution: Check that the device is powered on.
Verify proper cable connections.
ENEB—Non-existent GPIB board
Cause: GPIB board is not recognized.
Solution: Make sure that GPIB board settings and configuration setup
parameters agree.
EOIP—Function not allowed while I/O is in progress
Cause: An illegal call is made during an asynchronous I/O operation.
Solution: Only ibstop, ibwait, and ibonl calls are allowed during
asynchronous I/O operations. The driver must be resynchronized by
calling one of the following:
ibwait (mask contains CMPL)—The driver and
application are synchronized.
ibstop—The asynchronous I/O is canceled, and the
driver and application are synchronized.
ibonl—The asynchronous I/O is canceled, the interface
is reset, and the driver and application are synchronized.
Re-synchronization is successful if a CMPL is returned to
ibsta.
ECAP—No capability for operation
Cause: A call attempts to use a capability which is not supported by the
GPIB board.
Solution: Don't use the call.