Appendix C IBERR
GPIB-488 C-3 Programming Reference Manual
ENOL—No listening device(s)
Cause: The routine detected no listeners.
Solution: Verify the following:
Make sure that a device has been addressed properly.
Check that at least two-thirds of the devices on the GPIB
bus are turned on, including the specified device.
Make sure that all connections are secure.
Verify the device(s) GPIB address.
Make sure that the device was properly configured.
EADR—GPIB interface board not addressed
Cause: The GPIB interface board has not been addressed.
Solution: Call ibcmd and address the board.
If you are calling
i/jointfilesconvert/1732015/bgts, with shadow handshaking enabled, call
ibcac.
EARG—Invalid argument
Cause: An invalid parameter has been provided to a routine.
Solution: Check syntax and range of parameters. See Chapter 3, GPIB 488.1
Library Reference, and Chapter 4, GPIB 488.2 Library Reference.
ESAC—Board is not the system controller
Cause: Routine requires that the GPIB interface board is the system
controller.
Solution: Configure the board to be the system controller.