DataShuttle and DynaRes
11-12-01
QuickLog Introduction 10-3
Specifications
Meter Display Screens
Types of I/O Supported Analog In, Analog Out, Digital In, Digital Out, Counter/Timer pulse input,
Counter/Timer frequency input, and Time.
Maximum Number of Data Acquisition Devices 15
Maximum Number of Channels Per Board 160. Channel name and/or units may be typed in.
Analog Input Ranges Supported all that are supported by the data acquisition driver.
Analog Input Resolution Supported all that are supported by the data acquisition driver.
Analog Output Ranges Supported all that are supported by the data acquisition driver
Scaling of Any Input Type linear, y = mX + b.
Outputs (analog or digital) may be changed by typing the value into the digital meter.
Size of Digital Meter Display selectable height and width.
Number of Digital Meters selectable from 1 to 100.
Chart Display Screen
Single chart with selectable time scale. Y axis is % of specified range or user entered maximum and
minimum range. Includes the scaling specified in the digital meter display.
Chart is a window that may be sized as desired.
Types of I/O Supported Analog In, Digital In, Counter/Timer pulse input.
Number of Traces Displayed 14 maximum.
Logging
Data Type ASCII characters, tab-delimited.
Maximum Number of Logged Channels 256
Log Rate same as sample rate
Types of I/O Supported Analog In, Digital In, Counter/Timer pulse input.
DDE
Any meters may be linked to another application using DDE.
Inputs can be sent, and outputs can be received, from the other source.
DDE Rate same as sample rate, or same as rate requested by other application.
General Configuration
The following settings are available for the general configuration of QuickLog:
Sample rate: same for all channels, inputs and outputs,
Polled or synchronous mode for all types: Analog In, Analog Out, Digital In, Digital Out,
Counter/Timer pulse input, Counter/Timer frequency input,
Polled mode: maximum speed is several samples/second,
Interrupt mode: maximum speed is several hundred samples/second,
Number of input meters,
Input meter font size,
Log file name, and
Number of output meters.
Output meter font size.