USB-1208FS-Plus User's Guide Specifications
23
Analog output
Table 8. Analog output specifications
250 S/s single channel typ, PC dependent
Power on and reset voltage
Note 4: Maximum throughput when scanning is machine dependent.
Table 9. Analog output accuracy, all values are (±); accuracy tested at no load
Table 10. Analog output accuracy components, all values are (±)
Note 5: Zero-scale offsets may result in a fixed zero-scale error producing a "dead-band” digital input code
region. In this case, changes in digital input code at values less than 0x040 may not produce a
corresponding change in the output voltage. The offset error is tested and specified at code 0x040.
Digital input/output
Table 11. Digital I/O specifications
16 (Port A0 through A7, Port B0 through B7)
2 banks of 8. Port B is high current drive.
Pull up/pull-down configuration
All pins pulled up to 5V via 47 kΩ resistors (default). Change to pull-down using
internal user-configurable jumpers.
Input high voltage threshold
Input low voltage threshold
–0.5 V absolute min
0 V recommended min
Output high voltage, Port A
4.4 V min (IOH = –20 µA)
3.84 V min (IOH = –6.0 mA)
Output low voltage, Port A
0.1 V max (IOL = 20 µA)
0.33 V max (IOL = 6.0 mA)
Output high voltage, Port B
4.4 V min (IOH = –50 µA)
3.76 V min (IOH = –24.0 mA)
Output low voltage, Port B
0.1 V max (IOH = 50 µA)
0.44 V max (IOH = 24.0 mA)
Commentaires sur ces manuels