CIO-DAC02 User's Guide Installing the CIO-DAC02 10 In the default configuration shown in Figure 2, addresses 9 and 8 are DOWN, and all others ar
CIO-DAC02 User's Guide Installing the CIO-DAC02 11 Voltage reference jumpers The output voltage of the D/A converters is determined by the value
CIO-DAC02 User's Guide Installing the CIO-DAC02 12 Connecting the board for I/O operations Connectors, cables – main I/O connector The table bel
13 Chapter 3 Functional Details Analog outputs Each D/A converter has three analog outputs; a unipolar voltage, a bipolar voltage and a 4-20 mA curre
CIO-DAC02 User's Guide Functional Details 14 A minimum of 8 VDC and a maximum of 36 VDC external excitation voltage is used to power the loop. A
15 Chapter 4 Specifications All specifications are subject to change without notice. Typical for 25 °C unless otherwise specified. Specifications in
CIO-DAC02 User's Guide Specifications 16 Environmental Table 3. Environmental specifications Operating temperature range 0 to 70 °C Storage temp
Declaration of Conformity Manufacturer: Measurement Computing Corporation Address: 10 Commerce Way Suite 1008 Norton, MA 02766 USA Category
Measurement Computing Corporation 10 Commerce Way Suite 1008 Norton, Massachusetts 02766 (508) 946-5100 Fax: (508) 946-9500 E-mail: [email protected]
CIO-DAC02 Analog Output Board User's Guide Document Revision 5, March, 2010 © Copyright 2010, Measurement Computing Corporation
3 HM CIO-DAC02.doc Your new Measurement Computing product comes with a fantastic extra — Management committed to your satisfaction! Thank you for cho
4 Trademark and Copyright Information TracerDAQ, Universal Library, Measurement Computing Corporation, and the Measurement Computing logo are either
5 Table of Contents Preface About this User's Guide ...
6 Preface About this User's Guide What you will learn from this user's guide This user's guide explains how to install, configure, and
7 Chapter 1 Introducing the CIO-DAC02 Overview: CIO-DAC02 features The CIO-DAC02 provides two channels of 12-bit analog voltage or current output. Ea
8 Chapter 2 Installing the CIO-DAC02 What comes with your CIO-DAC02 shipment? The following items are shipped with the CIO-DAC02. Hardware CIO-DAC
CIO-DAC02 User's Guide Installing the CIO-DAC02 9 Unpacking the CIO-DAC02 As with any electronic device, you should take care while handling to