WLS-TEMP Specifications
28
Temperature alarms
Table 11. Temperature alarm specifications
8 (one per digital I/O line)
Each alarm controls its associated digital I/O line as an alarm output. The input to each
alarm may be any of the analog temperature input channels. When an alarm is enabled, its
associated I/O line is set to output (after the device is reset) and driven to the appropriate
state determined by the alarm options and input temperature. The alarm configurations are
stored in non-volatile memory and are loaded at power on. Alarms will function both in
wireless mode and while attached to USB.
Alarm when input temperature > T1
Alarm when input temperature > T1, reset alarm when input temperature goes below T2
Alarm when input temperature < T1
Alarm when input temperature < T1, reset alarm when input temperature goes above T2
Alarm when input temperature is < T1 or > T2
Note: T1 and T2 may be independently set for each alarm.
Disabled, digital I/O line may be used for normal operation
Enabled, active high output (digital I/O line goes high when alarm conditions met)
Enabled, active low output (digital I/O line goes low when alarm conditions met)
Memory
Table 12. Memory specifications
1,024 bytes isolated micro reserved for sensor configuration
256 bytes USB micro for external application use
Microcontroller
Table 13. Microcontroller specifications
Three high performance 8-bit RISC microcontrollers
Wireless communications
Table 14. Wireless Communications specifications
IEEE 802.15.4, ISM 2.4GHz frequency band, non-beacon, point-to-point
Indoor/urban: Up to 150' (50 m)
Outdoor RF line-of-sight: Up to 1/2 mile (750 m)
–100 dBm (1% packet error rate)
12 direct sequence channels available, channels 12 – 23 (2.410 – 2.465 GHz)
(software selectable)
16-bit PAN (personal area network) IDs per channel (software selectable)
64-bit device address
128-bit AES (software selectable)