Measurement-computing Digital488/80A Manuel d'utilisateur Page 58

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 106
  • Table des matières
  • DEPANNAGE
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 57
CAUTION
Because the Configuration (C) command is used, the following programming
example(s) will not work properly if the HVCX1 option is installed with a conflicting
hardware configuration. To be safe, remove the HVCX1 board and replace it with the
jumper board to run the example(s).
EXAMPLE 5: Command Conflict Error.
PRINT#1,"OUTPUT08;G0C5P1X"
Line 1: Configure all 5 ports as outputs; select Port 1 only.
PRINT#1,"OUTPUT08;D123456ZX"
Line 2: Send too much data for one port.
PRINT#1,"OUTPUT08;E?"
Line 3: Query the error status (ERROR LED should be on).
PRINT#1,"ENTER08",
INPUT#2,A$,
PRINT A$
Line 6: Display shows: E3-Conflict Error (ERROR LED should
be off).
52 Digital488/80A Commands
967695 Digital488/80A User's Manual
Vue de la page 57
1 2 ... 53 54 55 56 57 58 59 60 61 62 63 ... 105 106

Commentaires sur ces manuels

Pas de commentaire