Measurement-computing PC104-PDISO8 Manuel d'utilisateur Page 11

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 20
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 10
3.2.1 ON & OFF for FORM C RELAYS
On means that FORM C relay common is in contact with the Normally-Open
(NO) contact.
Off means that FORM C relay common is in contact with the
Normally-Closed (NC) contact.
3.2.2 ON & OFF FOR FORM A RELAYS
On means that FORM A relay common is in contact with the Normally-Open
(NO) contact.
Off means that FORM A relay common is open.
3.3 INPUT REGISTER
The isolated input register is located at
BASE
address + 1.
WRITE = NO FUNCTION
READ = STATUS: Read the status of the isolated inputs. A one in the input bit
position indicates that a voltage is present at the input.
INPUT #
7 6 5 4 3 2 1 0
BIT No. 76543210
HEX 804020108421
DECIMAL 1286432168421
7
Vue de la page 10
1 2 ... 6 7 8 9 10 11 12 13 14 15 16 ... 19 20

Commentaires sur ces manuels

Pas de commentaire