Chapter 2 Signal Conditioning VIs
ADAC LabVIEW VI
8
5
ADAC RTD Conv (Convert RTD Reading)
This VI Converts the specified RTD Source Voltage(s) input array into temperature units.
Source Voltage(s) Source Voltage(s) is a one-dimensional array containing the input
data in volts to be converted into temperature.
Units (0:celsius) Units specifies the desired temperature units for the conversion. The
available options are:
0:Celcius Celsius degree
1:Fahrenheit Fahrenheit degree
2:Kelvin Kelvin degree
3:Rankine Rankine
The default Units is 0:Celcius
error in (no error) Error in describes error conditions occurring before this VI executes.
This cluster defaults to no error.
Temperature(s) Destination buffer is a one-dimensional array containing the converted
data in the specified temperature units.
error out Error out contains error information. If the error in cluster indicated an error,
the error out cluster contains the same information. Otherwise, error out describes the
error status of this VI.