Measurement-computing CIO-DAS801 Manuel d'utilisateur

Naviguer en ligne ou télécharger Manuel d'utilisateur pour Matériel Measurement-computing CIO-DAS801. Measurement Computing CIO-DAS801 User Manual Manuel d'utilisatio

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer

Résumé du contenu

Page 2 - CIO-DAS801

CIO-DAS801 User's Guide Installing the CIO-DAS801 10 5436987SWA9A8A7A6A5A4A3HEX2001008040201008 Figure 1. Base address switches In the default c

Page 3 - HM CIO-DAS801.doc

CIO-DAS801 User's Guide Installing the CIO-DAS801 11 The CIO-EXP16 and CIO-EXP32 were designed to interface to a single-ended input. Failure to

Page 4

CIO-DAS801 User's Guide Installing the CIO-DAS801 12 Interrupt level In order to take advantage of high speed transfers, you must provide the bo

Page 5 - Table of Contents

CIO-DAS801 User's Guide Installing the CIO-DAS801 13 Installing the CIO-DAS801 After you configure the board's switches and jumpers, you ca

Page 6 - About this User's Guide

CIO-DAS801 User's Guide Installing the CIO-DAS801 14 37 CH0 HI36 35 34 33 32 31 30 29 PC +528 DGND27 DIN326 DIN225 DIN1 / Trig24 I

Page 7 - Introducing the CIO-DAS801

15 Chapter 3 Functional Details Analog inputs Analog inputs on the CIO-DAS801 are designed to accept voltage signals for measurement. The analog inpu

Page 8

CIO-DAS801 User's Guide Functional Details 16 Digital inputs and outputs All the digital inputs and outputs on the CIO-DAS801 are TTL level. TTL

Page 9 - Configuring the CIO-DAS801

CIO-DAS801 User's Guide Functional Details 17 Figure 8. Counter/timer circuit

Page 10 - Input configuration

18 Chapter 4 Specifications All specifications are subject to change without notice. Typical for 25°C unless otherwise specified. Specifications in

Page 11

CIO-DAS801 User's Guide Specifications 19 Parameter Specification Unipolar 10 V 100% / 99.96% / 4 bins 1 V 100% / 99.59% / 4 bins 0.1 V 99.95

Page 12 - 2 3 4 5 6 7 X

CIO-DAS801 Analog Input and Digital I/O User's Guide Document Revision 1, March, 2010 © Copyright 2010, Measurement Computing Corporation

Page 13 - Installing the CIO-DAS801

CIO-DAS801 User's Guide Specifications 20 Power consumption Table 4. Power consumption specifications +5 V quiescent 500 mA typical, 750 mA max

Page 14

Declaration of Conformity Manufacturer: Measurement Computing Corporation Address: 10 Commerce Way Suite 1008 Norton, MA 02766 USA Category

Page 15 - Functional Details

Measurement Computing Corporation 10 Commerce Way Suite 1008 Norton, Massachusetts 02766 (508) 946-5100 Fax: (508) 946-9500 E-mail: [email protected]

Page 16 - Counter/timer circuit

3 HM CIO-DAS801.doc Your new Measurement Computing product comes with a fantastic extra — Management committed to your satisfaction! Thank you for ch

Page 17

4 Trademark and Copyright Information TracerDAQ, Universal Library, Measurement Computing Corporation, and the Measurement Computing logo are either

Page 18 - Specifications

5 Table of Contents Preface About this User's Guide ...

Page 19 - Counters

6 Preface About this User's Guide What you will learn from this user's guide This user's guide explains how to install, configure, and

Page 20 - Main connector and pin out

7 Chapter 1 Introducing the CIO-DAS801 Overview: CIO-DAS801 features The CIO-DAS801 provides eight channels of 12-bit analog input, seven digital I/O

Page 21 - Declaration of Conformity

8 Chapter 2 Installing the CIO-DAS801 What comes with your CIO-DAS801 shipment? The following items are shipped with the CIO-DAS801. Hardware  CIO-

Page 22

CIO-DAS801 User's Guide Installing the CIO-DAS801 9 Unpacking the CIO-DAS801 As with any electronic device, you should take care while handling

Modèles reliés CIO-DAS802 | CIO-DAS802/16 |

Commentaires sur ces manuels

Pas de commentaire